Nylon and pvc conduits
Flexible corrugated conduit IP66/IP67/IP68/IP69. The corrugated conduit PA6V2-HCF-HCC is manufactured in specially modified polyamide 6 PA6 MOD BS [V2] in compliance with the norms EN IEC 61386-2-3. Usable particularly for static and frequently fl exing applications exposed to heavy impact and compression forces. The self-extinguishing material quality allows applications with demanding requirements within the ship-building, machine engineering application, and renewable energy industry. The product displays excellent mechanical resistance to impacts, particularly in cold and dry environments. The material is self-extinguishing and free of halogen and cadmium. Usage temperature range: from –45°C to +105°C. Self-extinguishing and non-flame propagating in compliance with UL 1696 and EN IEC 61386, certificate equivalent standard: Meets with the requirements of BS EN 61386 – 2 – 3 and BS 731 Part 1.
θ int.- Internal diameter of the conduit
θ est.- External diameter of the conduit
NW – Nominal diameter of the conduit
Material: Polyamide 6 MOD BS C (PA6 MOD BS C)
Color: Black
Operating temperature: – 50 °C / + 105 °C
Temperature (Short period) IS FIP: 150°C (500h), 165°C (100h)
Degree of protection IP: IP66/IP67/IP68/IP69
Material: Polyamide 6 MOD BS C (PA6 MOD BS C)
Color: Black
Reference standard: EN IEC 61386-23, UL 1696
Classification codes EN IEC 61386: 2 4 5 3
Compressive strength: 320 N
Impact resistance: 6 J
Impact resistance at -45°C: 2 J
Tensile strength EN IEC 61386 (Da NW 17 mm): 500 N
Tensile strength EN IEC 61386 (NW 7, 10,12 mm): 200 N
Halogen-Cadmium Free: Yes
Fire characteristic of the product UL 1696: Yes
Fire classification UL94: V2
Self-extinguishing FMVSS 302: Yes
Glow wire test IEC 60695: 850 °C
Spread of fire EN IEC 61386: non flame propagating
UV and weathering performance IS FIP: Average to good (5-10 anni)
Traction test for the conduit system (conduit and fitting) and compression resistance tests in accordance with the EN IEC 61386 standard.
Registration, Evaluation, Authorization and Restriction of Chemicals
Resistenza alle radiazioni UV
Restriction of Hazardous Substances directive
Fittings for Conduits
Fittings for Conduits
Fittings for Conduits
Fittings for Conduits
Fittings for Conduits
Nylon and pvc conduits
Nylon and pvc conduits
Nylon and pvc conduits
Nylon and pvc conduits
Fittings for Conduits
Nylon accessories and components for fittings and cable glands
Nylon accessories and components for fittings and cable glands
Nylon accessories and components for fittings and cable glands
Nylon accessories and components for fittings and cable glands
Nylon accessories and components for fittings and cable glands
Nylon accessories and components for fittings and cable glands
Nylon accessories and components for fittings and cable glands
Nylon accessories and components for fittings and cable glands