Fittings for Conduits

Fitting type cable gland AM RP MG

Fitting cable gland with swivel male thread for flexible conduit IP66/IP67/IP68. It can be used wherever it is necessary to block a cable with a cable gland and to protect it, at the same time, into a covered flexible metal conduit. The thread swivel is useful for installations that need to support the continuous movement of the conduit together with cables (torsion or movement). It can be used wherever there is a threaded hole, by screwing it directly or a passing hole by means of a locknut on the opposite side. They are made up by nickel-plated brass and IP rating, certified according to norms EN IEC 61386, between fitting and cable is IP66 / IP67 / IP68 and it is assured by a thermosetting elastomer rubber that tightens on cable and by sealing ring that tightens on conduit when you tighten nut, so that you can assure a perfect mechanical resistance to traction, torsion and vibration. Instead the electrical continuity is assured by an internal ferrule screwing on the internal metal structure of the conduit and covers the whole edge of the flexible conduit to protect cable passage.

θ int.- Internal diameter of the conduit
θ Min-Max – Cable passage range
F – Thread Type and Thread Size
Types of threads: ISO Metric (ISO 965), GAS (ISO 228)
Material: Nickel plated brass
Color: Nickel

θ int(mm)

θ int(mm)

Select Thread(F)

Lf(mm)

Lf(mm)

θ min(mm)

θ min(mm)

θ max(mm)

θ max(mm)

Product code

CAD

θ int(mm)

10

Thread(F)

GAS (ISO 228)

Size(F)

GAS 1/4”

Lf(mm)

9

θ min(mm)

5

θ max(mm)

8

Product code

50060-TR.210

CAD

CAD 3D

θ int(mm)

12

Thread(F)

GAS (ISO 228)

Size(F)

GAS 3/8”

Lf(mm)

9

θ min(mm)

8

θ max(mm)

10.5

Product code

50061-TR.212

CAD

CAD 3D

θ int(mm)

12

Thread(F)

GAS (ISO 228)

Size(F)

GAS 1/2”

Lf(mm)

9

θ min(mm)

8

θ max(mm)

10.5

Product code

50062-TR.212

CAD

CAD 3D

θ int(mm)

15.5

Thread(F)

GAS (ISO 228)

Size(F)

GAS 1/2”

Lf(mm)

9

θ min(mm)

7.5

θ max(mm)

13

Product code

50063-TR.216

CAD

CAD 3D

θ int(mm)

20.5

Thread(F)

GAS (ISO 228)

Size(F)

GAS 3/4”

Lf(mm)

9

θ min(mm)

12.5

θ max(mm)

18

Product code

50064-TR.221

CAD

CAD 3D

θ int(mm)

26.5

Thread(F)

GAS (ISO 228)

Size(F)

GAS 1”

Lf(mm)

11

θ min(mm)

17.5

θ max(mm)

23

Product code

50065-TR.227

CAD

CAD 3D

θ int(mm)

34.5

Thread(F)

GAS (ISO 228)

Size(F)

GAS 1” 1/4

Lf(mm)

11

θ min(mm)

27.5

θ max(mm)

33

Product code

50066-TR.235

CAD

CAD 3D

θ int(mm)

39.5

Thread(F)

GAS (ISO 228)

Size(F)

GAS 1” 1/2

Lf(mm)

11

θ min(mm)

30.5

θ max(mm)

36

Product code

50067-TR.240

CAD

CAD 3D

θ int(mm)

50.5

Thread(F)

GAS (ISO 228)

Size(F)

GAS 2”

Lf(mm)

11

θ min(mm)

43

θ max(mm)

48.5

Product code

50068-TR.250

CAD

CAD 3D

θ int(mm)

10

Thread(F)

PG (DIN 40430)

Size(F)

PG9

Lf(mm)

9

θ min(mm)

5

θ max(mm)

8

Product code

50080-TR.210

CAD

CAD 3D

θ int(mm)

12

Thread(F)

PG (DIN 40430)

Size(F)

PG11

Lf(mm)

9

θ min(mm)

8

θ max(mm)

10.5

Product code

50081-TR.212

CAD

CAD 3D

θ int(mm)

12

Thread(F)

PG (DIN 40430)

Size(F)

PG13,5

Lf(mm)

9

θ min(mm)

8

θ max(mm)

10.5

Product code

50082-TR.212

CAD

CAD 3D

θ int(mm)

15.5

Thread(F)

PG (DIN 40430)

Size(F)

PG13,5

Lf(mm)

9

θ min(mm)

7.5

θ max(mm)

13

Product code

50083-TR.216

CAD

CAD 3D

θ int(mm)

15.5

Thread(F)

PG (DIN 40430)

Size(F)

PG16

Lf(mm)

9

θ min(mm)

7.5

θ max(mm)

13

Product code

50084-TR.216

CAD

CAD 3D

θ int(mm)

20.5

Thread(F)

PG (DIN 40430)

Size(F)

PG21

Lf(mm)

9

θ min(mm)

12.5

θ max(mm)

18

Product code

50085-TR.221

CAD

CAD 3D

θ int(mm)

26.5

Thread(F)

PG (DIN 40430)

Size(F)

PG29

Lf(mm)

11

θ min(mm)

17.5

θ max(mm)

23

Product code

50086-TR.227

CAD

CAD 3D

θ int(mm)

34.5

Thread(F)

PG (DIN 40430)

Size(F)

PG36

Lf(mm)

11

θ min(mm)

27.5

θ max(mm)

33

Product code

50087-TR.235

CAD

CAD 3D

θ int(mm)

39.5

Thread(F)

PG (DIN 40430)

Size(F)

PG42

Lf(mm)

11

θ min(mm)

30.5

θ max(mm)

36

Product code

50088-TR.240

CAD

CAD 3D

θ int(mm)

50.5

Thread(F)

PG (DIN 40430)

Size(F)

PG48

Lf(mm)

11

θ min(mm)

43

θ max(mm)

48.5

Product code

50089-TR.250

CAD

CAD 3D

θ int(mm)

10

Thread(F)

Metrico (ISO 965)

Size(F)

M16x1,5

Lf(mm)

9

θ min(mm)

5

θ max(mm)

8

Product code

50090-TR.210

CAD

CAD 3D

θ int(mm)

12

Thread(F)

Metrico (ISO 965)

Size(F)

M16x1,5

Lf(mm)

9

θ min(mm)

8

θ max(mm)

10.5

Product code

50091-TR.212

CAD

CAD 3D

θ int(mm)

12

Thread(F)

Metrico (ISO 965)

Size(F)

M20x1,5

Lf(mm)

9

θ min(mm)

8

θ max(mm)

10.5

Product code

50092-TR.212

CAD

CAD 3D

θ int(mm)

15.5

Thread(F)

Metrico (ISO 965)

Size(F)

M20x1,5

Lf(mm)

9

θ min(mm)

7.5

θ max(mm)

13

Product code

50093-TR.216

CAD

CAD 3D

θ int(mm)

20.5

Thread(F)

Metrico (ISO 965)

Size(F)

M25x1,5

Lf(mm)

9

θ min(mm)

12.5

θ max(mm)

18

Product code

50094-TR.221

CAD

CAD 3D

θ int(mm)

26.5

Thread(F)

Metrico (ISO 965)

Size(F)

M32x1,5

Lf(mm)

11

θ min(mm)

17.5

θ max(mm)

23

Product code

50095-TR.227

CAD

CAD 3D

θ int(mm)

34.5

Thread(F)

Metrico (ISO 965)

Size(F)

M40x1,5

Lf(mm)

11

θ min(mm)

27.5

θ max(mm)

33

Product code

50096-TR.235

CAD

CAD 3D

θ int(mm)

39.5

Thread(F)

Metrico (ISO 965)

Size(F)

M50x1,5

Lf(mm)

11

θ min(mm)

30.5

θ max(mm)

36

Product code

50097-TR.240

CAD

CAD 3D

θ int(mm)

50.5

Thread(F)

Metrico (ISO 965)

Size(F)

M63x1,5

Lf(mm)

11

θ min(mm)

43

θ max(mm)

48.5

Product code

50098-TR.250

CAD

CAD 3D

Characteristics

Operating temperature: – 40 °C / + 105 °C
Degree of protection IP: IP66/IP67/IP68
Material: Nickel plated brass
Color: Nickel
Reference standard: EN IEC 61386
Classification codes EN IEC 61386: 4 4 4 3
Tensile strength: 1000 N
Impact resistance: 6 J
Self-extinguishing EN IEC 61386: Flame retardant
Electrical characteristics: Guarantee electrical continuity
Corrosion resistance: Excellent

Quality controls

Salt Spray and Salt Fog Testing: UNI EN ISO 9227:2017 (NSS). Periodic tests on each production lot relating to traction at 1000 N and compression at 1250 N in accordance with the EN IEC 61386 standard on all closed systems consisting of conduits and fittings and cable gland fittings and traction test (cable anchoring for unarmoured cable - cable retention class B) and shore tests for the sealing rubber in accordance with EN / IEC 62444 on all closed systems consisting of cable glands.

Certifications

Federal Executive Body (Russian Federation) - Gost-R POCC IT.HB56.H01066

Registration, Evaluation, Authorization and Restriction of Chemicals

Restriction of Hazardous Substances directive

Related products

It may also interest you

Read our articles.