Fittings for Conduits
Fitting cable gland with fixed female thread for flexible conduit IP66/IP67/IP68. It can be used wherever it is necessary to block a cable with a cable gland and to protect it, at the same time, into a covered flexible metal conduit. The thread swivel is useful for installations that need to support the continuous movement of the conduit together with cables (torsion or movement). It can be used wherever there is a threaded hole, by screwing it directly or a passing hole by means of a locknut on the opposite side. They are made up by nickel-plated brass and IP rating, certified according to norms EN IEC 61386, between fitting and cable is IP66 / IP67 / IP68 and it is assured by a thermosetting elastomer rubber that tightens on cable and by sealing ring that tightens on conduit when you tighten nut, so that you can assure a perfect mechanical resistance to traction, torsion and vibration. Instead the electrical continuity is assured by an internal ferrule screwing on the internal metal structure of the conduit and covers the whole edge of the flexible conduit to protect cable passage.
θ int.- Internal diameter of the conduit
θ Min-Max – Cable passage range
F – Thread Type and Thread Size
Lf – Thread length
Types of threads: ISO Metric (ISO 965), GAS (ISO 228), NPT (ANSI/ASME B1.20.1), GAS Conico (ISO 7-1) – Rc
Material: Nickel plated brass
Color: Nickel
θ int(mm)
10
Thread(F)
GAS (ISO 228)
Size(F)
GAS 1/4”
Lf(mm)
10
θ min(mm)
5
θ max(mm)
8
Product code
50151-TR.210
CAD
θ int(mm)
12
Thread(F)
GAS (ISO 228)
Size(F)
GAS 3/8”
Lf(mm)
10
θ min(mm)
8
θ max(mm)
10.5
Product code
50153-TR.212
CAD
θ int(mm)
12
Thread(F)
GAS (ISO 228)
Size(F)
GAS 1/2”
Lf(mm)
10
θ min(mm)
8
θ max(mm)
10.5
Product code
50154-TR.212
CAD
θ int(mm)
15.5
Thread(F)
GAS (ISO 228)
Size(F)
GAS 1/2”
Lf(mm)
10
θ min(mm)
7.5
θ max(mm)
13
Product code
50155-TR.216
CAD
θ int(mm)
20.5
Thread(F)
GAS (ISO 228)
Size(F)
GAS 3/4”
Lf(mm)
10
θ min(mm)
12.5
θ max(mm)
18
Product code
50156-TR.221
CAD
θ int(mm)
26.5
Thread(F)
GAS (ISO 228)
Size(F)
GAS 1”
Lf(mm)
12
θ min(mm)
17.5
θ max(mm)
23
Product code
50157-TR.227
CAD
θ int(mm)
34.5
Thread(F)
GAS (ISO 228)
Size(F)
GAS 1” 1/4
Lf(mm)
12
θ min(mm)
27.5
θ max(mm)
33
Product code
50158-TR.235
CAD
θ int(mm)
39.5
Thread(F)
GAS (ISO 228)
Size(F)
GAS 1” 1/2
Lf(mm)
14
θ min(mm)
30.5
θ max(mm)
36
Product code
50159-TR.240
CAD
θ int(mm)
50.5
Thread(F)
GAS (ISO 228)
Size(F)
GAS 2”
Lf(mm)
14
θ min(mm)
43
θ max(mm)
48.5
Product code
50160-TR.250
CAD
θ int(mm)
10
Thread(F)
GAS Conico (ISO 7-1)
Size(F)
Rc 1/4”
Lf(mm)
10
θ min(mm)
5
θ max(mm)
8
Product code
50193-TR.210
CAD
θ int(mm)
12
Thread(F)
GAS Conico (ISO 7-1)
Size(F)
Rc 3/8”
Lf(mm)
10
θ min(mm)
8
θ max(mm)
10.5
Product code
50194-TR.212
CAD
θ int(mm)
15.5
Thread(F)
GAS Conico (ISO 7-1)
Size(F)
Rc 1/2”
Lf(mm)
13.75
θ min(mm)
7.5
θ max(mm)
13
Product code
50195-TR.216
CAD
θ int(mm)
20.5
Thread(F)
GAS Conico (ISO 7-1)
Size(F)
Rc 3/4”
Lf(mm)
13.75
θ min(mm)
12.5
θ max(mm)
18
Product code
50196-TR.221
CAD
θ int(mm)
26.5
Thread(F)
GAS Conico (ISO 7-1)
Size(F)
Rc 1”
Lf(mm)
17.6
θ min(mm)
17.5
θ max(mm)
23
Product code
50197-TR.227
CAD
θ int(mm)
34.5
Thread(F)
GAS Conico (ISO 7-1)
Size(F)
Rc 1” 1/4
Lf(mm)
17.6
θ min(mm)
27.5
θ max(mm)
33
Product code
50198-TR.235
CAD
θ int(mm)
39.5
Thread(F)
GAS Conico (ISO 7-1)
Size(F)
Rc 1” 1/2
Lf(mm)
18.5
θ min(mm)
30.5
θ max(mm)
36
Product code
50199-TR.240
CAD
θ int(mm)
50.5
Thread(F)
GAS Conico (ISO 7-1)
Size(F)
Rc 2”
Lf(mm)
20.5
θ min(mm)
43
θ max(mm)
48.5
Product code
50200-TR.250
CAD
θ int(mm)
10
Thread(F)
NPT (ANSI/ASME B1.20.1)
Size(F)
NPT 1/4”
Lf(mm)
10
θ min(mm)
5
θ max(mm)
8
Product code
50252-TR.210
CAD
θ int(mm)
12
Thread(F)
NPT (ANSI/ASME B1.20.1)
Size(F)
NPT 3/8”
Lf(mm)
10
θ min(mm)
8
θ max(mm)
10.5
Product code
50253-TR.212
CAD
θ int(mm)
12
Thread(F)
NPT (ANSI/ASME B1.20.1)
Size(F)
NPT 1/2”
Lf(mm)
13.75
θ min(mm)
8
θ max(mm)
10.5
Product code
50254-TR.212
CAD
θ int(mm)
15.5
Thread(F)
NPT (ANSI/ASME B1.20.1)
Size(F)
NPT 1/2”
Lf(mm)
13.75
θ min(mm)
7.5
θ max(mm)
13
Product code
50255-TR.216
CAD
θ int(mm)
20.5
Thread(F)
NPT (ANSI/ASME B1.20.1)
Size(F)
NPT 3/4”
Lf(mm)
13.75
θ min(mm)
12.5
θ max(mm)
18
Product code
50256-TR.221
CAD
θ int(mm)
26.5
Thread(F)
NPT (ANSI/ASME B1.20.1)
Size(F)
NPT 1”
Lf(mm)
17.6
θ min(mm)
17.5
θ max(mm)
23
Product code
50257-TR.227
CAD
θ int(mm)
34.5
Thread(F)
NPT (ANSI/ASME B1.20.1)
Size(F)
NPT 1” 1/4
Lf(mm)
17.6
θ min(mm)
27.5
θ max(mm)
33
Product code
50258-TR.235
CAD
θ int(mm)
39.5
Thread(F)
NPT (ANSI/ASME B1.20.1)
Size(F)
NPT 1” 1/2
Lf(mm)
18.5
θ min(mm)
30.5
θ max(mm)
36
Product code
50259-TR.240
CAD
θ int(mm)
50.5
Thread(F)
NPT (ANSI/ASME B1.20.1)
Size(F)
NPT 2”
Lf(mm)
20.5
θ min(mm)
43
θ max(mm)
48.5
Product code
50260-TR.250
CAD
θ int(mm)
12
Thread(F)
Metrico (ISO 965)
Size(F)
M16x1,5
Lf(mm)
10
θ min(mm)
8
θ max(mm)
10.5
Product code
50301-TR.212
CAD
θ int(mm)
15.5
Thread(F)
Metrico (ISO 965)
Size(F)
M16x1,5
Lf(mm)
10
θ min(mm)
7.5
θ max(mm)
13
Product code
50302-TR.216
CAD
θ int(mm)
15.5
Thread(F)
Metrico (ISO 965)
Size(F)
M20x1,5
Lf(mm)
10
θ min(mm)
7.5
θ max(mm)
13
Product code
50303-TR.216
CAD
θ int(mm)
20.5
Thread(F)
Metrico (ISO 965)
Size(F)
M20x1,5
Lf(mm)
10
θ min(mm)
12.5
θ max(mm)
16
Product code
50304-TR.221
CAD
θ int(mm)
20.5
Thread(F)
Metrico (ISO 965)
Size(F)
M25x1,5
Lf(mm)
10
θ min(mm)
12.5
θ max(mm)
18
Product code
50305-TR.221
CAD
θ int(mm)
26.5
Thread(F)
Metrico (ISO 965)
Size(F)
M25x1,5
Lf(mm)
12
θ min(mm)
17.5
θ max(mm)
21
Product code
50306-TR.227
CAD
θ int(mm)
26.5
Thread(F)
Metrico (ISO 965)
Size(F)
M32x1,5
Lf(mm)
12
θ min(mm)
17.5
θ max(mm)
23
Product code
50307-TR.227
CAD
θ int(mm)
34.5
Thread(F)
Metrico (ISO 965)
Size(F)
M40x1,5
Lf(mm)
12
θ min(mm)
27.5
θ max(mm)
33
Product code
50308-TR.235
CAD
θ int(mm)
39.5
Thread(F)
Metrico (ISO 965)
Size(F)
M50x1,5
Lf(mm)
14
θ min(mm)
30.5
θ max(mm)
36
Product code
50309-TR.240
CAD
θ int(mm)
50.5
Thread(F)
Metrico (ISO 965)
Size(F)
M63x1,5
Lf(mm)
14
θ min(mm)
43
θ max(mm)
48.5
Product code
50310-TR.250
CAD
Operating temperature: – 40 °C / + 105 °C
Degree of protection IP: IP66/IP67/IP68
Material: Nickel plated brass
Color: Nickel
Reference standard: EN IEC 61386
Classification codes EN IEC 61386: 4 4 4 3
Tensile strength: 1000 N
Impact resistance: 6 J
Self-extinguishing EN IEC 61386: Flame retardant
Electrical characteristics: Guarantee electrical continuity
Corrosion resistance: Excellent
Salt Spray and Salt Fog Testing: UNI EN ISO 9227:2017 (NSS). Periodic tests on each production lot relating to traction at 1000 N and compression at 1250 N in accordance with the EN IEC 61386 standard on all closed systems consisting of conduits and fittings and cable gland fittings and traction test (cable anchoring for unarmoured cable - cable retention class B) and shore tests for the sealing rubber in accordance with EN / IEC 62444 on all closed systems consisting of cable glands.
Federal Executive Body (Russian Federation) - Gost-R POCC IT.HB56.H01066
Registration, Evaluation, Authorization and Restriction of Chemicals
Restriction of Hazardous Substances directive
Flexible Metal Conduits
Flexible Metal Conduits
Flexible Metal Conduits
Flexible Metal Conduits
Nylhom junction boxes
Fittings for Conduits
Fittings for Conduits
Fittings for Conduits
Fittings for Conduits
Metal accessories for fittings and cable glands
Metal accessories for fittings and cable glands
Metal accessories for fittings and cable glands
Nylon accessories and components for fittings and cable glands
Metal accessories for fittings and cable glands
Metal accessories for fittings and cable glands
Metal accessories for fittings and cable glands
Metal accessories for fittings and cable glands