Fittings for Conduits
Straight fitting with metal female thread corrugated flexible conduit IP66/IP67/IP68/IP69. The one-piece cable protection conduit fitting with a metric metal female thread, made of brass nickel plated and specially modified, halogen-free Polyamide 6, is self-extinguishing and resistant against most chemical media commonly used. Due to its excellent UV-resistance, it is also perfectly suited for outdoor installations. With the brand new 360° interlocking system and an inside conduit seal, it complies with the highest possible protection class IP69 in combination with our corrugated conduits. Being delivered pre-assembled and easy to re-open by using a commercially available slotted screwdriver, it ensures significant time saving during installation and disassembly. Available in Metric and PG version.
NW – Nominal diameter of the conduit
θ ID – Maximum cable passage
F – Thread Type and Thread Size
Lf – Thread length
Material: Polyamide 6 MOD V0 SGA (PA6 MOD V0 SGA)
Color: Black / Grey
Operating temperature: – 50 °C / + 120 °C
Temperature (Short period) IS FIP: 150°C (500h), 160°C (100h)
Degree of protection IP: IP66/IP67/IP68/IP69
Material: Polyamide 6 MOD V0 SGA (PA6 MOD V0 SGA)
Color: Black / Grey
Reference standard: EN IEC 61386, UL1696
Tensile strength: 500 N
Notched bar impact test ISO 180: 7-25 KJ/m2
Halogen-Cadmium Free: Yes
Fire classification UL94: V0
Fire characteristic of the product UL1696: Self-extinguishing
Self-extinguishing FMVSS 302: Self-extinguishing
Oxygen index EN ISO 4589-2: >32%
Glow wire test IEC 60695: 960 °C
Fire hazardous level EN 45545-2: HL3 R22, HL3 R23
Self-extinguishing EN IEC 61386: Flame retardant
Flame spread index ASTM E162 (NFPA 130): Compliant
Smoke densitiy ASTM E662 (NFPA 130): Compliant
Toxicity BSS 7239/SMP 800-C: Compliant
Heat release ASTM E1354 (50 Kw/m2): 19,4 MJ/Kg (8265 BTU/lb)
UV and weathering performance IS FIP: Excellent (40 anni)
Traction test for the conduit system (conduit and fitting) and compression resistance tests in accordance with the EN IEC 61386 standard.
American Society for Testing and Materials
Halogen free
National Fire Protection Association
Registration, Evaluation, Authorization and Restriction of Chemicals
Resistenza alle radiazioni UV
Restriction of Hazardous Substances directive
Standards for rolling stock (halogen free) EN 45545-2
Fittings for Conduits
Fittings for Conduits
Fittings for Conduits
Fittings for Conduits
Nylon and pvc conduits
Nylon and pvc conduits
Nylon and pvc conduits
Nylon and pvc conduits
Nylon accessories and components for fittings and cable glands
Nylon accessories and components for fittings and cable glands
Nylon accessories and components for fittings and cable glands
Nylon accessories and components for fittings and cable glands