Fittings for Conduits
45° Straight fitting with male thread corrugated flexible conduit IP66/IP67/IP68/IP69. Our one-piece 45° fitting from specially modified, halogen-free Polyamide 6 is self-extinguishing and resistant to the most commonly used chemical media. Due to its excellent UV resistance, this fitting can also be installed outdoors without hesitation. With our newly developed 360 ° locking system and an inner tube seal, it meets the highest protection class IP69 in conjunction with our corrugated tubes in fine and coarse profiles. Its clip is easy to close and re-open by means of a screwdriver and this peculiarity implies significant time savings during the installation process. It is available in three threads version: PG, ISO, and NPT, and in two colors: black and grey.
NW – Nominal diameter of the conduit
θ ID – Maximum cable passage
F – Thread Type and Thread Size
Lf – Thread length
Material: Polyamide 6 MOD V0 SGA (PA6 MOD V0 SGA)
Color: Black / Grey
NW(mm)
12
Thread(F)
NPT (ANSI/ASME B1.20.1)
Size(F)
NPT 1/2”
Lf(mm)
13.5
Product code
P45401
NW(mm)
36
Thread(F)
NPT (ANSI/ASME B1.20.1)
Size(F)
NPT 1” 1/4
Lf(mm)
18
Product code
P45404
NW(mm)
48
Thread(F)
NPT (ANSI/ASME B1.20.1)
Size(F)
NPT 1” 1/2
Lf(mm)
18.4
Product code
P45405
NW(mm)
17
Thread(F)
NPT (ANSI/ASME B1.20.1)
Size(F)
NPT 1/2”
Lf(mm)
13.5
Product code
P45501
Operating temperature: – 50 °C / + 120 °C
Temperature (Short period) IS FIP: 150°C (500h), 160°C (100h)
Degree of protection IP: IP66/IP67/IP68/IP69
Material: Polyamide 6 MOD V0 SGA (PA6 MOD V0 SGA)
Color: Black / Grey
Reference standard: EN IEC 61386, UL1696
Tensile strength: 500 N
Notched bar impact test ISO 180: 7-25 KJ/m2
Halogen-Cadmium Free: Yes
Fire classification UL94: V0
Fire characteristic of the product UL1696: Self-extinguishing
Self-extinguishing FMVSS 302: Self-extinguishing
Oxygen index EN ISO 4589-2: >32%
Glow wire test IEC 60695: 960 °C
Fire hazardous level EN 45545-2: HL3 R22, HL3 R23
Self-extinguishing EN IEC 61386: Flame retardant
Flame spread index ASTM E162 (NFPA 130): Compliant
Smoke densitiy ASTM E662 (NFPA 130): Compliant
Toxicity BSS 7239/SMP 800-C: Compliant
Heat release ASTM E1354 (50 Kw/m2): 19,4 MJ/Kg (8265 BTU/lb)
UV and weathering performance IS FIP: Excellent (40 anni)
Traction test for the conduit system (conduit and fitting) and compression resistance tests in accordance with the EN IEC 61386 standard.
American Society for Testing and Materials
Halogen free
National Fire Protection Association
Registration, Evaluation, Authorization and Restriction of Chemicals
Resistenza alle radiazioni UV
Restriction of Hazardous Substances directive
Standards for rolling stock (halogen free) EN 45545-2
Fittings for Conduits
Fittings for Conduits
Fittings for Conduits
Fittings for Conduits
Fittings for Conduits
Nylon and pvc conduits
Nylon and pvc conduits
Nylon and pvc conduits
Nylon and pvc conduits
Nylon accessories and components for fittings and cable glands
Nylon accessories and components for fittings and cable glands
Nylon accessories and components for fittings and cable glands
Nylon accessories and components for fittings and cable glands